●Easy to use UK socket tester. Enables you to safely check if the earth, live and neutral wires are correctly wired on any UK plug socket. Just plug the tester into the socket, switch on and the results appear instantly. Gives you reassurance and peace of mind on the safety and condition of your connections. CE certified.
●Clear and easy to read visual indication, so no chance of misreading the results. Distinctive markings give a clear indication of the condition of a sockets wiring without having to unscrew the socket panel from the wall. So great for testing multiple sockets quickly and efficiently!
●RCD or earth leakage circuit breaker test facility to ensure the correct operation of the main distribution or fuse board.
●Comes with an easy to follow user guide to help identify faults. The outlet tester can be used to detect whether the live, neutral or earth wire is connected correctly or if any are missing or reversed. 220-250v Voltage range, specifically for the UK.
●No bigger than a 13 amp plug so easy to transport and store. Every maintenance or DIY mans tool kit should have one! Package Content: 1 x Earth Potential UK Outlet Tester and 1 x Instruction Manual. Dimensions: 55 x 55 x 60mm (L x W x D). Ideal Gift.


Description

Earth Potential’s 13amp UK socket tester is designed to be simple to use and understand. Just plug the tester into the socket, turn the socket on and the results are displayed immediately. It is safe to use as there is no need to unscrew the socket from the wall to check the connections. The tester will indicate the presence of live, neutral and ground connections as well as polarity reversals and missing connections. For a correctly wired socket the indications should read (left to right) Unlit, Green, Green. If the tester shows any other result we strongly advice that you contact a qualified electrician to investigate and correct the fault. An RCD, or earth leakage circuit breaker test facility is also included. Simply press and hold the button on the front of the tester for a couple of seconds. If the RCD breaker is working correctly the indicators on the tester should all go out indicating the loss of power to the socket. Power may also have been lost at other sockets in the area. Don’t forget to turn the breaker back on again at the buildings distribution board after the test in order to restore power to the tested circuit! The AST01UK is designed to fit a standard UK 13amp socket and operates on 220 to 250 volt power.